The Reliability of the Titan 1+ 10 Hz Global Positioning System for Measures of Distance and Distance within Speed Zones

The International Journal of Strength and Conditioning is the only academic journal in S&C and Sport Science to be 'Diamond' Open Access. We have recently published a new article by Elia, V., Cappaert, T., Neeld, K., & Harmon, M. C. (2024). titled, "The Reliability of the Titan 1+ 10 Hz Global Positioning System for Measures of Distance and Distance within Speed Zones".

Abstract

Introduction: This experiment was designed to investigate the inter and intra-unit reliability of the Titan 1+ 10 Hz global positioning system (GPS) for measures of distance and distance within speed zones during straight-line and change of direction running at varying distances and speeds, as well as during a team-sport simulated circuit.

Methods and Materials: 16 male NCAA collegiate soccer players completed running protocols of varying distances and speeds, including long and short duration straight-line running (100m Run and SLR), tight and gradual change of direction running (COD T and COD G), and a team-sport simulated circuit (TSSC).

Results: Between Titan 1+ devices, good to moderate interunit reliability was established for distance measures during the 100m run (%CV = 1.31). Moderate to high-speed movements for 20m SLR (5.2 – 7.4%), and all movements speed across the 40m SLR (3.5 – 4.5%). Good interunit reliability for distance measures was also established during both COD courses (2.04 – 3.6%). Good to moderate interunit reliability for distance within speed zones was established for COD G speed zone 4 (%CV = 6.8%) and COD T in speed band 3 (%CV = 7.1%). Moderate to excellent intraunit reliability was reported for distance within speed zones 2 and 3 during SLR (p < 0.05), with moderate intraunit reliability for 10m (.605 ICC, p = .004) and 40m (.620 ICC, p = .007). During the COD G, distance intraunit reliability was moderate for jogging and sprinting (.649 ICC, p = .004; .649 ICC, p = .002, respectively). Distances within speed zones 2 and 3 during COD G intraunit reliability was excellent for zone 2 (.956 ICC, p < .001) and zone 3 (.905, p < .001). During the TSSC, intraunit reliability was good for lap distance (.805 ICC, p < .001). Good intraunit reliability was reported for distance in speed zone 2 (.840 ICC, p < .001) and excellent for zone 3 (.919 ICC, p < .001) and zone 4 (.901 ICC, p < .001).

Conclusions: The present study is known to be the first to investigate the intra-unit reliability of distance measures during a team-sport simulated circuit. The findings suggest that the Titan 1+ provides good intraunit reliability for measures of distance and good to excellent intraunit reliability for measures of distance within speed zones during the TSSC. Further, the Titan 1+ produced reliable distance measures across all running protocols both within and between devices.


Click the link below to read the full article:

 




 
 

Comments


Sponsors

full-logo-black-orange.png
HawkinDynamics_Logo_Horizontal_Black_RGB_edited.png

Company Number: 11260654

International Universities Strength and Conditioning Association

Carnegie School Of Sport, G17 Fairfax Hall, Leeds Beckett University, Headingley Campus, Church Wood Avenue, Leeds, England, LS6 3QT

All purchases can be returned within 14 days.

Please email courses@iusca.org for more info. 

  • twitter
  • LinkedIn
  • Black Instagram Icon
  • facebook

©2019 by International Universities Strength and Conditioning Association

bottom of page